|
|
Protection against spillsManagers of industrial or railroad facilities handling oil, fuel and chemicals are aware that event he most careful procedures cannot totally eliminate spills in areas where rail cars and locomotives are loaded, unloaded, washed or fueled. It's a serious problem because the spilled substances can damage the environment as well as cross ties and equipment.
SynTechnics FRP (Fiberglas Reinforced Plastic) Track Collector Pan Systems offer protection by collecting and isolating spills for treatment and disposal. Properly installed to connect with permanent waste treatment systems, they can limit environmental problems caused by uncollected spillage, and reduce downtime for equipment repair. |
|
|
Simple, efficient systemsSystem components include collector pans that attach to rails and cross drains that connect with pre-installed underground pipes or trenches. Substances flow to a sump or collection tank for treatment or disposal.
Through years of field experience and testing, the SynTechnics FRP Track Collector Pan Systems have been developed and refined to achieve design simplicity and system economy. The FRP Systems offer the following advantages over alternative methods:
|
|
|
Corrosion resistanceFiberglass has earned a reputation for its resistance to corrosion from aggressive substances. The SynTechnics FRP track Collector Pan System stands up against many chemicals that would prove highly destructive to steel or concrete systems. SynTechnics. manufacturing process makes use of specially selected resins which resist corrosion in customer-specified chemical environments. In these specific applications, customer testing for compatibility will verify their performance of the resins. |
Easy installation, minimal maintenanceInstallation of SynTechnics FRP Track Collector Pan Systems requires minimal downtime. Because fiberglass is lightweight, a small crew can install the system without heavy handling equipment. Components can be removed and replaced, without damage, if cross ties need repair.
System components require little maintenance. Durability is not affected by temperatures between -50°F and +130°F. Any damage to components can be repaired with simple hand tools, Replacement components can be reordered within a short lead time. |
|
|
Center pan sectionSections are snapped into
place and "float" |
|
Side pan sectionPan sections are continuous
between cross ties. |
|
Drain cover/cross walkLiquids spilled on collector
pans flow along the |
|
Cross drainLiquids collect in the cross
drain, then flow |